  • Rated. / 5. Based on customer reviews
Page view 0
Model PLMS
Features
Light comes on when motion is detected.
Automatically controls existing post light.
Dual Light Level.
Photocell keeps the light off during day-
light hours.
This package includes:
240-031-A
© 2003 Atlas Lighting Products, Inc. 598-1095-01
Mode: On-Time Works: Day Night
Test 5 Sec x x
Auto 1, 5, or 20 Min x
Manual To Dawn* x
Accent 3,6 Hr, to Dawn x
OPERATION
* resets to Auto Mode at dawn.
TEST
AUTO
TEST 1 5 20 MIN
MANUAL MODE
1 Second
OFF
then
...
... back on.
Flip light switch
off for 1 second
then on
ON-TIME Switch at
1, 5, or 20 minutes
Mode Switching Summary
Dual Light Level Control
Light comes on half bright for selected time
after dusk (Off, 3 hr., 6 hr., until dawn). If
motion is sensed, the light turns on full bright
for the ON-TIME (1, 5, or 20 minutes) then
returns to dim mode.
Requirements
The Light Control requires 120 volts AC.
If you want to use Manual Override, the
control must be wired through a switch.
Some codes require installation by a
qualified electrician.
3 Wire Connectors
3 Screws
Post Light
Adapter
MANUAL MODE
AUTO
TEST
TEST 1 5 20
ON-TIME
Off 3 6 Dusk to Dawn
ACCENT
Put ON-TIME switch on the sensor bottom to
TEST and the Dual Light Level (ACCENT)
switch OFF.
* If you get confused while switching modes,
turn the power off for one minute, then back
on. After the calibration time the control will
be in the AUTO mode.
Set ON-TIME switch to
1, 5, or 20 minutes.
Manual mode only works at
night because daylight re-
turns the sensor to AUTO.
Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.
Manual mode works only with
the ON-TIME switch in the 1,
5, or 20 position.
GUARDIAN PRO
POST SENTRY
Page view 0
1 2 3 4

Summary of Contents

Page 1 - GUARDIAN PRO

Model PLMSFeatures• Light comes on when motion is detected.• Automatically controls existing post light.• Dual Light Level.• Photocell keeps the light

Page 2 - SPECIFICATIONS

2598-1095-01INSTALLATIONSPECIFICATIONSRange . . . . . . . . . . . Up to 30 ft. (9.1 m)[varies with surround-ing temperature]Sensing Angle . . . .

Page 3 - Plastic Post Lamps

3598-1095-01ADJUSTMENTS❒ Turn on the circuit breaker and lightswitch.NOTE: Sensor has a 1 1/2 minute warm upperiod before it will detect motion. Whenf

Page 4 - TROUBLESHOOTING GUIDE

4598-1095-01SYMPTOMLight stays oncontinuously.Light flasheson and off.POSSIBLE CAUSE1. The sensor is pointed at nearbyobjects that cause heat to trigg